Javascript required
Skip to content Skip to sidebar Skip to footer

Dragon Master Profile Cannot Be Reached Try Again When Network Resource Is Available

This iSupport solution is designed to assistance our Dragon Medical customers with fast ERROR identification and resolution, providing a unmarried source of searchable information through the Error Matrix beneath. Currently, at that place are two (ii) expandable tables:

To search for specific errors within the Fault Matrix, either click the table links to a higher place to jump directly to an individual tabular array and manually review the content...or, only apply your browser's Find office to search this folio for specific ERROR strings.

Additional errors will be continually added. The existing ERRORS presented in the individual tables below volition be updated to include workarounds and solutions equally they become available. Please revisit this solution periodically to check for changes to these ERRORS.

Iii (3) of the sections for each row are expandable expand button every bit indicated in a higher place.  Each expandable section tin can be expanded expand button and collapsed Minus button to display selected detail for specific topics or ERRORs.

Click the section's plus expand button buttons to expand and display additional information near a topic within each row.
Click the section'southward minus Minus button buttons to collapse the information.

In addition, at the meridian-right of each table, click the Expand All link to aggrandize all details for all tables on this folio, and click the Collapse All link to minimize all of the details.

The post-obit table describes the columns and their expandable sections presented in the error tables within this document:

  • Topics with tabular array links to iSupport solutions marked "Internal" will need to be addressed by Technical Support every bit these documents are not accessible to our customers. The post-obit error volition exist presented:

    You may not have permission to view this Solution. Please attempt to refresh the page. If you lot still cannot view the Solution, delight login and search for the Solution.

  • Further, customers should be logged into their iSupport accounts in order to view table links to iSupport solutions.
  • Table rows with empty Status and SOLUTION sections for a specific Mistake means that this ERROR has been reported. However, Nuance is presently not able to provide a response. In this case, delight submit a Service Asking and provide the dragon.log to Technical Support for analysis and investigation.
  • This article was made possible by Mike Geraghty.

    General ERRORS are whatever errors occurring inside the Dragon Medical production and its environmentthat do not include:

    Dragon Medical
    General ERRORS

    Fault and Clarification Product(south)
    Version(due south)
    Affected Condition / Workaround

    "Cancelled due to Node Restart"

    This ERROR can appear for all Profile Optimizer (PO) Tasks listed in the DM360NE Nuance Management Panel (NMC). This Error has been linked to DM360NE, versions ii.1 and 2.2, where version 12.51.200.072 of SDK client software for the PO server fails to perform Audio-visual and Linguistic communication Model Optimization (ACO/LMO) of DM360NE users created in DM360NE, version two.1 and 2.2.

    DM360NE
    2.1
    ii.2

    STATUS: SOLVED

    Upgrade DM360NE to version 2.3 which includes an updated SDK client software (v12.51.202.093).

    WORKAROUND: Non Currently

    "You are not allowed by the Administrator to run Dragon Medical Data Distribution Tool"

    The NMC Data Distribution Tool (Dichloro-diphenyl-trichloroethane) shows this login rights fault in primarily XP based workstations.

    DM360NE 1.ten

    STATUS: SOLVED

    This error can be resolved by editing a registry entry equally described below. Care should taken when editing the registry.

    On Windows XP machines that have issues starting Ddt, make the following registry change:

    1. Close all web browsers.
    2. Verify that PresentationHost.exe is non running in Job Manager (finish the procedure if nowadays).
    3. Offset regedit. (You lot must be a Windows administrator.)
    4. Create a DWORD value nether HKLM\Software\Microsoft\.NETFramework\Windows Presentation Foundation\Hosting\RunUnrestricted = 1
    5. No reboot should be necessary.

    For a mergeable registry edit file, encounter iSupport Solution 14115: NMC Distribution Tool (DDT) shows logon rights error

    WORKAROUND: Not Currently

    "Unable to annals the Citrix Client Update, C:\Program Files\Citrix\ICA Customer\vddns.dll"

    "Could not annals Citrix audio module. Please contact your arrangement administrator for more than information."

    Trying to manually register vddns.dll returns the following error:

    "DllRegisterServer in C:\Program Files\Citrix\ICA Client\vddns.dll failed. Return lawmaking was 0x80004005"

    This message tin can announced when trying to install the Dragon Medical Citrix Audio Patch (Vddnspatch.exe or Vddnspatch.msi) on a workstation with the Citrix ICA Client, regardless of whether the patch is installed by msi or by running the executable.

    DM360NE
    DMPE

    Condition: SOLUTION Pending

    WORKAROUND: Yeah

    The version of Dragon Medical Citrix Audio Patch must support the version of Citrix ICA Customer installed on the workstation. Reference the Dragon Medical Citrix Ambassador Guide for supported versions of Citrix components.  Further, confirm the version of Dragon Citrix Audio Patch is equal to, or higher than, the installed Dragon Medical client on the XenApp server.

    "User profile is not set up for dictation"

    This message tin appear when opening a user contour on the Dragon Medical customer and tin can be caused past multiple reasons such every bit:

    • The Audio Setup Wizard was canceled or paused, to be resumed at a after time.
    • After completing the Audio Setup Magician, Dragon Medical is unable to save the microphone settings to the Dragon user profile.
    • The previously configured microphone is no longer connected to the computer, or is no longer existence detected by the Operating System.
    DM360NE
    DMPE

    Condition: SOLVED

    Apply these steps to confirm proper microphone setup and configuration in Dragon Medical:

    1. Confirm that the microphone is connected to the computer.

      Note: If the previously configured microphone is no longer available, it may exist necessary to create a new Dictation Source for the user profile if the Dictation Source types are different (for example, the original blazon is was a "USB microphone" while the new type is a "Bluetooth Microphone".

      Meet iSupport solution 16541: Adding an Additional Dictation Source in Dragon Medical.

    2. Ostend the Windows Operating System has correctly detected the microphone.

      Come across iSupport solution 14252: Resolving USB Device detection issues where Dragon Medical is installed.

    3. Ostend the microphone is working properly outside of Dragon.

      See iSupport solution 13029: Unable to complete the Audio Setup Wizard.

    4. When Dragon prompts to run the Sound Setup Wizard, complete all of the steps in order to finalize the sound setup.
    5. One time the Audio Setup is completed, click Profile > Save User Profile to verify the profile is saved.

    "Dragon has encountered an error and may become unstable"

    This is a general error category.

    DM360NE
    DMPE STATUS: SOLUTION PENDING  

    WORKAROUND: Yes

    Delight submit a Service Asking and provide the dragon.log to Technical Back up as this error requires log file analysis, and investigation of the user's environment and workflow on a per-incident occurrence.

    "Windows has recovered from an unexpected shutdown."

    This is a general error category.

    DM360NE
    DMPE Condition: SOLUTION PENDING  

    WORKAROUND: Yes

    Please submit a Service Asking and provide the dragon.log to Technical Support as this mistake requires log file analysis, and investigation of the user's environs and workflow on a per-incident occurrence.

    "Increase Acoustic Archive Size"
    "You demand to increment the size of the acoustic archives"

    DM360NE
    DMPE Status: SOLUTION PENDING  

    WORKAROUND: Not Currently

    "Error has occurred initializing session"

    DM360NE
    DMPE Condition: SOLUTION Pending  

    WORKAROUND: Non Currently

    "In ComCallFailed(), couldn't go the IDgnError"

    This mistake is usually a secondary notification every bit a event of another (sometimes more critical) error.

    DM360NE
    DMPE STATUS: SOLUTION Pending  

    WORKAROUND: Yeah

    Please submit a Service Request and provide the dragon.log to Technical Back up as this error requires log file analysis, and investigation of the user'south environment and workflow on a per-incident occurrence.

    "An exception occurred in ClsNASServices::NASConnectionThreadProc"

    Reported in conjunction with a "Server unavailable" message where down-version clients are attempting to authenticate to an up-version NMS. LDAP and the /trusted natspeak switch may exist involved.

    DM360NE Condition: SOLUTION Pending  

    WORKAROUND: Yes

    "m_pIPlayback->Stop() returned unexpected value E_UNEXPECTED (0x8000ffff) in "natspeak.exe" process."

    DM360NE
    DMPE Condition: SOLUTION PENDING  

    WORKAROUND: Not Currently

    "Fault (VBar): Unable to spawn 64 flake UIA server (0x80070102)"
    "Failed to launch 64 bit server"
    "Failed to launch UI Automation Server"

    Message can be presented during a new Dragon Medical installation on a 64-bit organization.

    "Failed to launch 64 Scrap Server" mistake tin as well occur under this scenario:

    1. Natspeak.exe crashes or is killed. DGNUIASVR_X64.EXE remains running.
    2. When Natspeak.exe is next run, it tries to beginning DGNUIASVR_X64.exe, but this fails since information technology's already running

    Besides, see step #10 in the WORKAROUND section when Windows viii.1 supgrades are involved.

    Likewise, if "Failed to launch 64 Bit Server" fault occurs within XenApp-published Dragon, or Dragon running in VDI, see step #eleven in the WORKAROUND section.

    DM360NE
    DMPE Status: SOLUTION Pending  

    "Fault (VBar): Unable to spawn 64 bit UIA server (0x80070102)"

    The error above is resolved for Dragon Medical 360 | Network Edition (DMNE), beginning in version 2.four.1.

    For access to the DMNE version 2.iv.1 release note and software download, delight refer to:

    iSupport solution #14274 - Dragon Medical 360 | Network Edition or Enterprise Edition - What'due south New and Tin can I download the Current Version?

    WORKAROUND: Yep

    1. Disable the User Contour Upgrade option during the start of the Dragon installation.
    2. For Dragon Medical software prior to version 12.50... on 64-bit (x64) clients, effort repairing the Visual C++ nine.0 Runtime component:
      1. Close all open applications or open up windows.
      2. Browse the Dragon Medical installation media or installation files for "ISSetupPrerequisites\VCRuntime" folders.
      3. Double click "vcruntime_x64.exe".
      4. Choose "Repair" and click "Next".
      5. Click "Install" and permit the repair finish.
      6. Reboot the computer.
    3. Try disabling UAC (User Access Control) completely (Never Notify)
    4. Unregister and re-annals the dll file: UIAutomationCore.dll from an Administrator command prompt:
    5. regsvr32 /u "C:\Windows\System32\UIAutomationCore.dll" to unregister
      regsvr32 "C:\Windows\System32\UIAutomationCore.dll" to re-annals

      AND

      regsvr32 /u "C:\Windows\SysWOW64\UIAutomationCore.dll" to unregister
      regsvr32 "C:\Windows\SysWOW64\UIAutomationCore.dll" to re-register

    6. Verify that there are no permission bug for the Windows user account at the following directory paths. Attempt granting the user account total access to that location for testing purposes.

      (32 Chip)
      C:\Program Files\Common Files\Dash\NaturallySpeaking12\dgnuiasvr.exe"

      (64 Bit)
      C:\Plan Files (x86)\Common Files\Nuance\NaturallySpeaking12\x64\ dgnuiasvr_x64.exe"

    7. Unregister and re-register the dll file: dgnuiax.dll from an Administrator command prompt:

      (32 Bit)
      regsvr32 /u "C:\Program Files\Common Files\Nuance\NaturallySpeaking12\dgnuiax.dll" to unregister

      regsvr32 "C:\Program Files\Common Files\Dash\NaturallySpeaking12\dgnuiax.dll" to re-register

      (64 Scrap)
      regsvr32 /u " C:\Program Files (x86)\Common Files\Nuance\NaturallySpeaking12\x64\dgnuiax_x64.dll" to unregister

      regsvr32 " C:\Programme Files (x86)\Common Files\Nuance\NaturallySpeaking12\x64\dgnuiax_x64.dll" to re-annals

    8. Confirm that the Windows user business relationship has total access to all of the locations listed in the to a higher place steps.
    9. Verify that the Windows user account has full access to the following registry location:

      HKEY_LOCAL_MACHINE\SOFTWARE\Classes\AppID\{03C140B2-4039-4AE3-A819-53BD10023E02}

      Confirm the following registry strings at the above registry location:

      (Default)=dgnuiasvr_x64.exe [or exe file in question]
      ROTFlags=1
      ServerPath=[the proper path to the UI server EXE]

        (64 Bit)
        C:\Program Files (x86)\Mutual Files\Dash\NaturallySpeaking12\dgnuiasvr.exe

        Note: A 32 bit system omits "(x86") from the file path.

    10. Verify the Windows user account has full admission to the following registry locations:

      (64 Fleck)
      •HKEY_CLASSES_ROOT\AppID\{03C140B2-4039-4AE3-A819-53BD10023E02}
      •HKEY_CLASSES_ROOT\Wow6432Node\AppID\{03C140B2-4039-4AE3-A819-53BD10023E02}
      •HKEY_LOCAL_MACHINE\SOFTWARE\Classes\AppID\{03C140B2-4039-4AE3-A819-53BD10023E02}
      •HKEY_LOCAL_MACHINE\SOFTWARE\Classes\Wow6432Node\AppID\{03C140B2-4039-4AE3-A819-53BD10023E02}

      (32 Flake)
      •HKEY_CLASSES_ROOT\AppID\{D72EC95C-C74B-4ABC-874A-3FE9222E9846}
      •HKEY_CLASSES_ROOT\Wow6432Node\AppID\{D72EC95C-C74B-4ABC-874A-3FE9222E9846}
      •HKEY_LOCAL_MACHINE\SOFTWARE\Classes\AppID\{D72EC95C-C74B-4ABC-874A-3FE9222E9846}
      •HKEY_LOCAL_MACHINE\SOFTWARE\Classes\Wow6432Node\AppID\{D72EC95C-C74B-4ABC-874A-3FE9222E9846}


    11. This error can too be caused when the User Account Control (UAC) is turned off during the procedure of upgrading to Windows viii.ane.

      Perform the steps below to turn on UAC in Windows 8.1:

      1. Press "Windows Fundamental + X" on your keyboard to display the Tools Carte du jour, and select Command Panel. Or, right-click the lower left corner of your monitor to display the Tools Bill of fare, and select Control Panel.
      2. Type "UAC" in the search field in the upper right corner of the window.
      3. Click Change User Account Command settings in the search results.
      4. To turn UAC on, drag the slider upward to the desired level of security, and click OK.
      5. You lot may be prompted to confirm your selection or enter an administrator password.
      6. Reboot your computer for the change to take effect.


    12. If this mistake occurs within XenApp-published Dragon, or Dragon running in VDI:

      The server or domain policy, registry settings, and/or third party Windows profile management software tin can restrict access or intermittently interfere with access to %appdata% directory path, and and then "DGNUIASVR_X64.EXE" can neglect to outset.

      The is caused past when "DGNUIASVR_X64.EXE" attempts to write its log messages only to the dragon.log file within %appdata% and this process doesn't read or utilize the "datalocations.ini" to override that path.

      If a customer tin't exclude the "Nuance" folder within %appdata% from interference by their Windows profile management software, and they've employed the "datalocations.ini" workaround, and then "DGNUIASVR_X64.EXE" will still write its messages to the old, standard "Dragon.log" file location. If some of its log writes fail, "DGNUIASVR_X64.EXE" volition fail to start.

    Meet iSupport Solution 12612: "Failed to launch UI automation server / 64 bit server" error when launching Dragon Medical.

    "COM returned an unexpected mistake Code: Details are DGNERR_INVALIDSPEAKER"

    DM360NE
    DMPE Status: SOLUTION PENDING  

    WORKAROUND: Not Currently

    "The application has failed to get-go because dgnmycmds.dll was not institute."

    DM360NE
    DMPE Status: SOLUTION Pending  

    WORKAROUND: Not Currently

    "An engine sink failed to unregister itself"

    DM360NE
    DMPE STATUS: SOLUTION PENDING  

    WORKAROUND: Yes

    Please submit a Service Asking and provide the dragon.log to Technical Support as this error requires log file analysis, and investigation of the user's environment and workflow on a per-incident occurrence.

    "The RPC server is unavailable"
    "COM returned an unexpected fault code: Details are The RPC server is unavailable"

    This is a general mistake that typically results from another error condition.

    DM360NE
    DMPE Condition: SOLUTION PENDING  

    WORKAROUND: Yes

    "The audio input device is not responding. Please make certain information technology is working and is properly connected to the computer."

    DM360NE
    DMPE Status: SOLUTION Awaiting  

    WORKAROUND: Not Currently

    "The Audio Setup Sorcerer has not even so been successfully run for this user and dictation source. We will give you the opportunity now."

    Message may be presented even if the ASW has previously been completed for this user on this computer with this dictation source. The contour'southward audio.ini file may be incomplete.

    DM360NE
    DMPE Status: SOLUTION PENDING  

    WORKAROUND: Yes

    "A required file X is missing or damaged. Setup cannot continue installation and will leave at present."

    Normally, the integrity is in question for the file identified (X) and the source media should exist downloaded once again or replaced.

    DM360NE
    DMPE Status: SOLVED / SOLUTION PENDING  

    Re-create the installation media contents to the local hard disk drive then perform a local installation. Otherwise, the software media is likely corrupted and should be downloaded once again.

    WORKAROUND: No

    "Warning: Roaming SetUpNewContainer file already exists"

    DM360NE
    DMPE STATUS: SOLUTION PENDING  

    WORKAROUND: Not Currently

    "HOOKERR_CANNOTINJECT"

    DM360NE
    DMPE STATUS: SOLUTION Pending  

    WORKAROUND: Non Currently

    "Invalid digital signature" error

    DM360NE
    DMPE STATUS: SOLUTION Pending  

    WORKAROUND: Not Currently

    "USBD_STATUS_XACT_ERROR"
    "deadlocking"

    An intermittent issue was reported in DMNE, version 12.50.200.055, where a VMware View VDI session was "deadlocking". This resulted in a loss of dictation for the provider. "Deadlocking" occurs when two (2) or more tasks permanently cake one another by each chore attempting to lock a resource in which the other tasks are too trying to lock. This issue is specific to the VMware View Agent software and its interaction with the Windows invitee operating organisation.

    DM360NE
    DMPE STATUS: SOLVED  

    An initial recommendation was to motion the dictation devices from the back EHCI (USB 2.0) ports to the forepart OHCI (USB 1.1) ports.

    Another recommendation was made to disable the EHCI function, forcing the device back to OHCI mode. Reducing the occurrence of "USBD_STATUS_XACT_ERROR" errors on the endpoint (client) is a workaround proposed by VMware and Teradici to decrease the likelihood of the problem being triggered in the guest operating organisation by the VMware View Agent.

    Disabling the EHCI role can exist accomplished from the Teradici Management Console. A reboot of the Zero Client volition result.

    Access to the Teredici knowledge Base article below explaining this requires a registered account.
    PCoIP TROUBLESHOOTING STEPS: USB peripherals (15134-933)

    Please come across iSupport Solution 16276: DMNE 2.ten VMware View VDI session "deadlocking" with dictation loss

    "Mistake while unpacking program, Code ii. Please report to author"

    This has been reported when launching a Dragon Medical client on a Windows Vista operating system.

    DM360NE
    DMPE STATUS: SOLUTION Awaiting  

    WORKAROUND: Yes

    Microsoft released a security update for Windows Vista on July 11, 2011 (KB2533623) that has caused problems with not being able to launch or install certain third party applications.

    The current solution is to remove this specific Microsoft update (KB2533623) following these steps:

    1. Click "Get-go > Command Panel > Programs and Features".
    2. Click the "View installed updates" link on the left side of the window.
    3. Locate the "Update for Windows Vista for x64-based Systems (KB2533623)" update.
    4. Select the KB2533623 update and then click the "Uninstall" button.
    5. Once the update has been removed, restart the estimator.
    6. After the figurer restarts, confirm that the Nuance Desktop application tin can at present exist launched or installed.

    Please see iSupport Solution 14540: "Error while unpacking program, Code ii. Please report to writer" mistake when launching or installing a Nuance product

    Error 1330 - A file that is required cannot be installed because the cabinet file [ENUGen~1.cab] has an invalid digital signature. This may indicate that the cabinet file is decadent. Error 24592 was returned by WinVerifyTrust.

    WinTrust Error 1330
    Fault 266 returned by WinVerifyTrust

    Error 1330 / 1329 / 1332 / 1335 / 1339

    The previous mistake messages have been reported when installing Dragon Medical clients. The specific cabinet file beingness referenced may be unlike from the one shown to a higher place [ENUGen~1.cab].

    The problem could also be that the file could not be verified considering information technology was signed with a new VeriSign certificate (Root Authority Certificate) that is by default not included in Windows operating system, or the certificate has expired.

    DM360NE
    DMPE Condition: SOLVED  

    Solution #1:

    The post-obit volition resolve most related errors:

    1. Confirm Windows Local Administrator rights are used on the workstation where Dragon Medical is being installed.
    2. The cabinet file may not exist read properly when the organization is accessing the DVD or installation media. Use a flat-file installation method to install Dragon Medical from the local hard bulldoze by copying the contents of the Dragon Medical software media (DVD) to the local hard drive of the workstation, and execute the setup.exe file from that location.
    3. During the Dragon Medical Install_Shield, use the Custom install as the Setup Blazon and select the "This feature volition be installed when required" for the Speech Files icon.
    4. Temporarily disable any antivirus / malware / spyware software, specially any real-time / endpoint protection.
    5. Uninstall the Windows Update KB978601 if present. This tin exist reinstalled after Dragon Medical is successfully installed.
    6. Reboot the calculator and close all non-essential applications.
    7. Uninstall any previous version of Dragon Medical software using a Dragon software remover tool. See iSupport Solution 14760: How to completely uninstall Dragon - Remover Tool
    8. If the chiffonier error occurs when installing from a download, the downloaded files may be decadent. Try downloading Dragon Medical media again and install from the new download.

    Solution #two:

    If Solution 1 does non allow a successful installation, there may be problem with Windows WinTrust on the system. The Dragon installer uses Windows WinTrust to verify that the chiffonier file'due south digital signature is valid. In some cases at that place may exist a problem with WinTrust detecting the file's valid digital signature.

    1. Open Internet Explorer past correct-clicking the icon or menu item and selecting the "Run equally administrator" option.
    2. Select Tools > Internet Options > Content.
    3. In the Certificates group, click the Certificates button.
    4. Select Trusted Root Certification Authorities tab.
    5. Select Global Sign Root CA from the list. You lot may need to scroll downwardly.
    6. In Document intended purposes group, click the View button.
    7. Select the Details tab.
    8. Click the Edit Properties... push.
    9. Under the Enable merely the following purposes radio push, check the box for Code Signing.
    10. Click OK > OK > Close > OK to salve changes and exit.

    Solution #iii:

    Finally, the problem may be that the installation cabinet file could not exist verified considering information technology was signed with a new VeriSign document (Root Dominance Certificate) that is either non included in the currently installed operating system, or that the certificate has expired. If the Trusted Root Certificate Regime' document has expired or is non-real, the post-obit problems can occur:

    • Disability to access the NMC Console
    • Inability to deploy Dragon Medical client via SCCM

    Normally Windows updates its list of Root Certificates automatically. Withal, this may not take been achieved if blocked past security features.

    Confirm that the "Update Root Certificates" component is enabled inside Windows as follows:

    1. Click First > Command Console > Add together or Remove Programs > Add/Remove Windows Components > Update Root Certificates.
    2. Otherwise, download the certificates update file manually from: "http://download.windowsupdate.com/msdownload/update/v3/static/trustedr/en/rootsupd.exe"

    Utilise the latest root certificate update from Microsoft every bit described in KB931125: http://www.microsoft.com/download/en/details.aspx?displaylang=en&id=3867

    Otherwise, run across the following iSupport Solutions:

      14540: "Fault while unpacking program, Code ii. Please written report to author" error when launching or installing a Dash production

      13013: "Error 1330" may appear when installing Dragon NaturallySpeaking 10

      14575: WinTrust Error 1330

    WORKAROUND: No

    0x80070520: A specified logon session does not exist. Information technology may already accept been terminated.

    The scheduled job did not run because an wrong countersign or user name was entered.

    Chore Scheduler validated the configuration for job "\NatSpeak_Optimizer_10_10_EBD1934C-33A2-4E21-8008-9C037A7CA0C" , only credentials could not be stored. User Action: Re-annals the task ensuring the credentials are valid. Additional Information: Fault Value: 2147943712.

    NatSpeak_Optimizer_10_10_4841AF18-C87F-43F2-8736-4F888F995E2.task" (schedmgr.exe) 1/xix/2012 2:00:00 AM ** ERROR **
    The attempt to log on to the account associated with the job failed, therefore, the task did not run.
    The specific error is: 0x8007052e: Logon failure: unknown user name or bad password.
    Verify that the task'southward Run-every bit name and countersign are valid and endeavour again.

    When attempting to create and salvage an Acoustic and Language Model Optimizer Scheduler job in the Dragon Medical Enterprise Edition (DMEE) product, the to a higher place error messages can occur.

    DM360NE
    DMPE STATUS: SOLVED  

    WORKAROUND: No

    Error 1726
    COM returned and unexpected error lawmaking...(RPC_S_CALL_FAILED, 1726)
    FORMFILLER: An error occurred

    Dragon Medical introduced a new feature in customer version 11 and higher where the user tin can select, correct, or format multiple recognized text matches, such equally repeating words or phrases. Dragon labels each case of repetitive text with superscript numbering allowing the user to simply say the number corresponding to the desired case. This feature uses the formfiller.exe process. Fault has been reported when DMPE (version xi.00.300.312) is asunder from a Roaming profile location (working off the locally buried profile) and the dictator selects a give-and-take appearing multiple times in the dictation. Dragon hangs and presents the error.

    Refer to DragonBar Assist Topics (Help > Help Topics) and search on "Formatting or correcting multiple text matches" for additional operational information.

    DM360NE
    DMPE Status: SOLVED  

    This issue has been stock-still in the version 12 customer software.

    WORKAROUND: Yes

    If this issue persists, disable the formfiller process:

    1. Go out Dragon Medical and open the nssystem.ini file.
    2. (Windows XP) C:\Documents and Settings\All Users\Application Information\Nuance\NaturallySpeakingXX

      (Windows 7) C:\ProgramData\Nuance\NaturallySpeakingXX

    3. Nether [Settings] add the post-obit line:

      Bear witness disambiguation numbers=0

    4. Launch Dragon Medical.

    Disabling the formfiller feature via the above nssystem.ini modification volition remove the superscript numbering feature also as the same error/symptoms. The user will be able to select a word that was dictated multiple times where Dragon highlights but the concluding instance of the repetitive word selected. The user can then speak "select previous" and "select next" commands to navigate between redundant instances of the selected word if needed.

    See iSupport Solution 14713: Workaround for DMPE "COM" and "1726" errors caused by formfiller.exe for additional dragon.log content.

    Mistake 1722
    Fault 1722. There is a problem with this Windows Installer parcel.

    This fault has been reported when installing:

    • Dragon Medical vSync MiniTracker on Citrix servers
    • Dragon Medical client
    DM360NE
    DMPE STATUS: SOLUTION PENDING  

    WORKAROUND: Yes

    For errors installing MiniTracker, meet iSupport Solution 14843: DM360NE Fault 1722 during installation of vSync MiniTracker component

    For errors installing Dragon Medical clients, use the following steps to disable Information Execution Prevention (DEP):

    1. Click on the Windows Start Menu, then open the Control Panel.
    2. Click Archetype View.
    3. Double-click System
      Note: For Windows Vista and higher, click Avant-garde Arrangement Settings in the Organisation window.
    4. On the System Properties dialog box, click on the Advanced tab.
    5. Click the Settings push in the Performance section.
    6. Click the Information Execution Prevention tab.
    7. Click Turn on DEP for essential Windows programs and services only.
    8. Click OK and OK to apply the changes
    9. Reboot the customer.
    10. Install Dragon Medical.

    Dragon NaturallySpeaking should not exist run in elevated mode

    This bulletin occurs when attempting to launch Dragon Medical using Windows User Account Control (UAC) and "Run as Ambassador" is selected for "natspeak.exe". "Run as Administrator" is not active by default, requiring the user to turn on this setting. Notwithstanding, this elevated privilege level is non needed to run Dragon NaturallySpeaking.

    Clicking the "Close" push button on the dialog box volition close the error, but Dragon will non launch.

    This message can also announced when logged in equally the local Administrator account on the system.

    DM360NE
    DMPE Condition: SOLVED  

    Please apply the post-obit steps to turn off the "Run as Administrator" setting:

    1. Click Starting time > Computer.
    2. Double-click the Local Disk C: drive.
    3. Scan to \Program Files(x86)\Dash\NaturallySpeakingXX\Program binder.
    4. Right-click natspeak.exe.
    5. Select Properties.
    6. Click the Compatibility tab.
    7. Articulate the checkbox for Run as Ambassador.
    8. Click OK.

    Note: It is not possible to run Dragon Medical when logged in as the Local Administrator account on Windows Vista, or college. We recommend creating a new user account on the system that is part of the Administrators group and running Dragon under this new user.

    See iSupport Solution 12630: "Dragon NaturallySpeaking should not be run in elevated mode" error message

    WORKAROUND: No

    Server Not Establish
    Verify that the specified server exists. The server name can not be empty.

    This DMNE messages tin exist presented when the NMS (Dash Management Server) software install shield is running only after the Database Server and Service Logon windows were completed and Next is clicked.

    The NMS installation log reveals the following lines (C:\Users\[Windows Acct.]\AppData\Local\Temp\1\NMSCInstallation.log):

    1: Reading the SQL script information from ISSQL Connection table...
    1: ISSQLRequirement table does not exist...

    Installing a service through an install shield like DMNE NMS, where information technology prompts to enter a network domain\username and password, may return a "Server not found" fault, interim equally if it cannot find the user login specified.

    This may happen more than often with workgroups. It tin can also occur when using any of the Browse buttons in that install shield, resulting in a message, "The list is empty."

    DM360NE
    STATUS: SOLVED  

    For browsing annihilation like groups or users, the ISNetApi needs the server proper name. For the server name to exist verified or browsed, the computer'south ComputerBrowser service is required. The ComputerBrowser service can exist disabled on some Windows operating systems by default (similar Windows Server 2008).

    To resolve this issue, the ComputerBrowser service should exist enabled under Windows services. The Printer and File Sharing from inside Control Panel > Network And Sharing Center (Windows 2008) may too need to be enabled.

    See iSupport Solution 14488: Did yous know how to resolve a "Server Not Institute" message during a DMENE NMS installation?

    WORKAROUND: No

    The server was unable to communicate with the POS

    Clarification

    This mistake is presented from the NMC Profile Optimizer Status window. This is typically acquired when the Profile Optimizer Server service is non running.

    DM360NE
    Condition: SOLVED  
    1. Ostend the Profile Optimizer Server service is running.
    2. Verify that the Showtime, Second, and Subsequent Failure settings nether the Recovery tab on the service's Properties window are set for Restart the Service.

    Monitoring of the DMNE services is important and tin help to eliminate reanimation causes. Nuance recommends that the following services exist monitored:

    • Nuance Direction Service > Nuance.NAS.Server.exe 8731 8051
    • Contour Optimizer Server > POService.exe 8001
    • Profile Optimizer Voice communication Node > POSpeechNode.exe 8000
    • Microsoft SQL > NuanceMC & NuancePODB 1433
    • Microsoft IIS > Nuance Management Console http://nms_server/nmc/customer.xbap 80

    WORKAROUND: No

    An error occurred in the application you were using

    This error is presented within your browser window (IE) when attempting to access the NMC.

    DM360NE Status: SOLVED

    This error can be solved by:

    • Adding the URL for the NMS website to your browser's (IE) Trusted Site list nether the Security tab.
    • Using the built-in navigational arrows and tabs when navigating within NMC, instead of using the browser Back push.

    WORKAROUND: No

    Unable to connect to the remote server.
    No connexion could exist made because the target machine actively refused it
    .

    DMNE client dragon.log excerpt:

    [NMS] [NMS] WebException:
    System.Net.WebException: Unable to connect to the remote server ---> Arrangement.Net.Sockets.SocketException: No connection could be made because the target machine actively refused information technology 172.31.thirty.xx:8051

    DM360NE STATUS: SOLVED  

    This error is generally caused when the Nuance Management Server service is stopped on the DMNE NMS server. To resolve this issue, start the Nuance Management Server service.

    WORKAROUND: No

    Either no user is loaded or the MyCommands back up is not available. The Script and Manage modes will be disabled.

    DM360NE
    DMPE STATUS: SOLVED / SOLUTION PENDING  

    Resovled issue by removing and reinstalling Dragon.

    Outset tried to repair Dragon Medical installation and run /fixguids, merely same consequence

    WORKAROUND: Non Currently

    Dragon Medical - Profile Open/Corruption ERRORS

    If a Dragon Medical user is unable to open their user profile, the kickoff step if to identify any error bulletin that accompanies this failure. Mostly, in that location are several categories of causes for the disability of Dragon Medical to open a user profile. This iSupport solution lists specific errors associated with each of these general categories presented below:

    • Internal Profile Corruption
    • Windows Folder Permissions
    • Profiles Cannot Be Accessed
    • Locked Profiles and Breaking the Lock
    • Missing PowerMic Ii Dictation Source / Unable to add Mic-In Dictation Source

    Otherwise, refer to the related iSupport solutions below for additional information on identification, resolution, restoration, and prevention of user profile corruption for the Dragon Medical products:

    Solution #16452 - Restoring Corrupted Profiles for Dragon Medical products
    Solution #16453 - Troubleshooting Profile Corruption Errors for Dragon Medical products
    Solution #16454 - Preventing Profile Abuse for Dragon Medical products
    Solution #15981 - Anti-Virus recommendations for Dragon Medical 360 | Network Edition
    Solution #16452 - Dragon Medical User Profile Errors: "cannot exist accessed" and "suspension the lock"
    Solution #16072 - Dragon Medical: Power Outage causes either missing PowerMic II Dictation Source or unable to add together Mic-in Dictation Source
    Solution #14831 - Dash'due south policy for simultaneous client contour logins

    Collapse All    Expand All

    Dragon Medical
    Profile Corruption ERRORs

    ERRORs and Description Product(due south)
    Version(s)
    Affected
    Solution

  • The speech engine returned the following fault: InvalidTopic
  • The spoken communication engine returned the post-obit error: Invalid directory
  • The spoken language engine returned the following error: Unexpected
  • The speech engine returned the post-obit error: NotAFile
  • The speech engine returned the following error: MissingVocFile
  • The speech engine returned the following error: StaticVocabularyFileMissing
  • The spoken communication engine returned the following mistake: 164
  • An internal recognizer error has occurred...
  • COM returned an unexpected error code: Details are DGNERR_TOPICNOTOPEN
  • Unable to open topic. Internal fault. See Dragon log for details
  • SDAPI Fault
  • Signal Processing Error
  • The vocabulary you have chosen...is incompatible or invalid
  • E_FAIL
  • E_UNEXPECTED
  • An error occurred while saving or copying user files. The files "C:\Documents and Settings\All Users\Application Information\Nuance\NaturallySpeakingXX\Users\User name\current\aco.ini" could non be copied to "C:\Documents and Settings\All Users\Application Information\Dash\NaturallySpeakingXX\Users\User name\tb\aco.ini".
  • Internal Profile Abuse

    The following errors can exist presented when some level of corruption has occurred inside the user profile. Profile abuse commonly means that one or more files, folders, indices, or other components are either missing, the version is mismatched, or the contents or component trounce are corrupted.

    DM360NE
    DMPE

    SOLUTION:

    To resolve this category of mistake typically requires that the Dragon Medical user profile be restored.

    Please encounter iSupport solution:
    16452: Restoring Corrupted Profiles for Dragon Medical products

  • An error occurred while saving or copying user files.
  • Cannot create subdirectory in the roaming user network directory:
  • The roaming user local directory cannot be on a network drive:
  • Cannot create subdirectory in the roaming user local directory:
  • An internal recognizer error has occurred. NaturallySpeaking may exist in an unstable state, so you should save your work immediately so close and restart the program.

    Windows Folder Permissions

    Dragon Medical clients that are not able to access their profile's folder structure will non be able to open their profile, and in about cases, will receive one of the post-obit error messages:

    • An error occurred while saving or copying user files.
      This full general fault may have provide boosted particular nigh the specific directory paths or files. Otherwise, the dragon.log file should be reviewed for this detail, if the appropriate permissions listed below in the Solution section accept been confirmed.
    • Cannot create subdirectory in the roaming user network directory:
      Windows (NTFS) Change permissions are not assigned to the roaming profile network directory. Either copy the roaming user files to a directory for which Change permissions do be, or enable sharing and Modify permissions on the current roaming user directory so that y'all tin can create and re-create users in it from another calculator on your network. The directions for turning sharing on for a directory are different for unlike versions of Windows. In full general, you right-click on the folder icon and open the properties dialog box for that binder. If there is a Sharing tab on the dialog box, click it and select the "Share this binder" option (the wording of the option label may vary). Finally, either click the Permissions button or the Security tab and select the Modify permission to read, write, create, and delete files in that directory or any of its sub-directories. An administrator level Windows account may be required. If yous have questions or cannot enable sharing, ask your system administrator for assist.
    • The roaming user local directory cannot be on a network bulldoze:
      Windows on the Dragon client attempted to create a local copy of the master roaming contour in a location that may not be accessible to your figurer. The local roaming profile is necessary for instances where the master roaming location out on the network is not attainable. Your local roaming profile must be accessible to your computer at all times.
    • Cannot create subdirectory in the roaming user local directory:
      Information technology ways that you do non have Change privileges in the local roaming profile directory. If you lot cannot enable Modify permission in the local roaming profile directory, you must choose a different location for the files.

      Too, please refer to the Microsoft article / download link below. It discusses a service called User Profile Hive Cleanup. This service helps to ensure the user sessions are completely terminated later on the user logs off of Windows:
      http://world wide web.microsoft.com/downloadS/details.aspx?FamilyID=1b286e6d-8912-4e18-b570-42470e2f3582&displaylang=en

    • An internal recognizer error has occurred. NaturallySpeaking may be in an unstable land, so you should save your work immediately then close and restart the programme.
      When performing boosted or "Special" spoken language preparation for users or creating a profile for a digital recorder, this error bulletin can occur when Dragon Medical is unable to write to a temporary file created for adapting the user profile. Users must have Windows Modify permissions to the location listed beneath:
      Windows XP - C:\Documents and Settings\All Users\Awarding Data\Nuance\NaturallySpeakingXX
      Windows Vista / 7 / eight - C:\ProgramData\Dash\NaturallySpeakingXX
    • The roaming user network directory is not available
      This bulletin indicates that the Dragon Medical customer is not able to access the network share in which the Master Profile resides. Likewise, see row below for lock file causes.

    Otherwise, follow the instructions in the row above to restore the user profile.

  • DM360NE
    DMPE

    SOLUTION:

    This category of fault typically is caused past inadequate Windows (NTFS) permissions for the Dragon Medical profile folders, files, and/or network share.

    Dragon Medical requires the ability to read, write, and modify folders, sub-folders and files within Nuance folder structures on the client workstation and on the main roaming contour locations (if applicative). Dragon Medical will demand to perform deportment such as:

    • Create new folders, sub-folders and files
    • Rename folders, sub-folders and files
    • Delete folders, sub-folders and file

    These actions are performed by Dragon Medical on the following folders (product dependent):

      Windows XP
      C:\Program Files\Nuance
      C:\Programme Files\Common Files\Dash
      C:\Documents and Settings\All Users\Application Information\Nuance
      C:\Documents and Settings\<Windows user>\Application Data\Dash

      Windows Vista / 7 / 8
      C:\Program Files (x86)\Dash
      C:\Program Files (x86)\Common Files\Nuance
      C:\ProgramData\Nuance
      C:\Users\<Windows user>\AppData\Roaming\Dash

      Local Chief Profile Enshroud

      If a Contour Local Cache location has been modified to a custom directory path, other than default, confirm that the appropriate permissions exist.

      A locally-cached Main Profile is maintained on each workstation be DMNE. In the case where network connectivity was lost, the DMNE user can continue to work from the Local Master contour. DMNE synchronizes information between the Master and Local user profiles by and large when the contour is opened, closed, or saved.

      Principal Contour location
      The DMNE Master Profile location is typically a data server with a network share that stores the DMNE Principal Profiles. Ostend that the advisable permissions exist.

    IMPORTANT:

    • Dragon Medical requires at to the lowest degree (minimally) Windows Modify permissions for all Windows user accounts that will be accessing the Dragon Medical folder structures stated above.
    • The customer is responsible for providing an environment for Dragon Medical where the appropriate permissions exist.
    • A Windows Administrator user account may be required to confirm and correct Windows permissions.
    • The customer's IT/IS personnel may need to be involved.

    For DMNE products, you can identify the Master Profile path (speech file location) assigned in the NMC:

    1. Log into the NMC.
    2. Click Sites > Organization Overview.
    3. Right-click the site name and click Details.
    4. Click the DM360 Network Edition tab.
    5. Expand the Primary User Profiles section.
    6. Click the Configure push to see the speech file location (instance below).
    7. Test admission to this oral communication file location from the customer computer by copying and pasting this value into the computer'southward First > Run window. If a network error message is presented (example below), acceptable Windows permissions are not granted to this Windows user account.

    Please meet iSupport solution:
    16453: Troubleshooting Profile Corruption Errors for Dragon Medical products

  • The user files you have selected cannot be accessed. This could be because you do not have sufficient privileges to apply them or considering they are currently being accessed by some other program.
  • The local cache files for the user you lot have selected cannot be accessed. This could exist because you do non have sufficient privileges to apply them or because they are currently being accessed past some other program.
  • The roaming user network directory is not available
    This message indicates that the Dragon Medical client is not able to access the network share in which the Master Profile resides. Also, run across row higher up for permissions causes.

    Profiles Cannot Be Accessed

    The previous errors tin can be presented when attempting to open up a Dragon Medical User Contour

  • DM360NE
    DMPE

    SOLUTION:

    This access mistake can occur for multiple reasons when attempting to open Dragon Medical User Profiles, including:

    • Contour is currently open up on another workstation
    • username.lck lock file exists
    • _DGNRenamed suffix on folder name or file name
    • Profile folder structure accessed by another application (Windows Explorer, etc.)
    • Insufficient Windows binder, file, and network share permissions
    • Anti-virus exclusions needed
    • Other Anti-virus conflicts with Dragon Medical
    • Electrical ability disruptions
    • Network drop-out / latency issues

    To eliminate each of these potential causes, please encounter iSupport solution:

    14646: Dragon Medical User Profile Errors: "cannot be accessed" and "intermission the lock"

    User <name> is locked, and thus cannot exist accessed

    Locked Profiles and Breaking the Lock

    This following bulletin can be presented to Roaming users when attempting to open their Dragon Medical profile on a workstation:

    User <proper noun> is locked, and thus cannot exist accessed

    The user is prompted to "break the lock" on their profile. This message is provided as a alert. This issue can be caused when a folder or file lock is placed on the Dragon Medical contour binder structure. This lock can originate from different sources.

    However, the well-nigh mutual cause is that the workstation is existence ungracefully (prematurely) shut downwards before Dragon Medical could consummate the save or synchronization action on the contour. The contour lock was not removed.

    Otherwise, other causes for locked profiles tin can include:

    • Workstation is ungracefully shut downwards before Dragon Medical could consummate the salve/synchronization action on the profile ( most mutual )
    • Inadequate system resources (CPU, retentiveness, disk space, paging file, etc.)
    • Electrical power disturbances
    • Profile currently opened on another workstation
    • username.lck lock file exists
    • _DGNRenamed suffix on binder proper name or file name
    • Profile binder structure locked by another application (Windows Explorer, etc.)
    • Insufficient Windows folder, file, and network share permissions
    • Aggressive anti-virus settings (exclusions needed)
    • Other Anti-virus conflicts with Dragon Medical
    • Electrical power disruptions
    • Network drop-out / latency issues
    • Opening a Dragon Medical profile on a lower version of Dragon Medical client
    DM360NE
    DMPE

    SOLUTION:

    The Dragon Medical pick "Ask before breaking locks on network users" is located nether Tools > Administrative Settings > Roaming tab and can be configured to prevent or allow this message. If enabled, the user will be prompted to interruption the lock when causes warrant. If this option is not enabled or if this message is presented and "Yes" is called as the response to break this lock, Dragon Medical will let the user to open their profile and begin to dictate.

    If the user chooses "No" as the response to not suspension the lock, the contour will non open until the crusade is resolved.

    Important:

    • Choosing to routinely break profile locks is not recommended and tin can event in contour corruption.
    • If this error continues, the source of the error must be adamant and addressed.


    To eliminate potential causes for this issue, please see iSupport Solution:

    14646: Dragon Medical User Profile Errors: "cannot be accessed" and "suspension the lock"

    Missing PowerMic 2 Dictation Source
    Unable to add together Mic-in Dictation Source

    Dragon Medical products (including DMNE, DMPE, and DMEE) can lose the Dictation Source function if a client workstation is affected by an electrical power disruption.

    Two (two) specific scenarios have been reported:

    • Can non add "Mic-in" as a Dictation source in the Open Users dialog window
    • PowerMic II Dictation Source is no longer present in the Open Users dialog window. The provider may see only the Mic-in Dictation Source, but not the PowerMic Ii. The provider can re-add the PowerMic II equally a new Dictation Source as it is displayed in the list of Dictation Sources. However, that PowerMic II Dictation Source is never populated into the Open Users dialog window.

    This issue can be identified in the dragon.log by the line:

    Mistake: missing SpeakerLanguageID in [Profile path]\electric current\options.ini

    This upshot is typically acquired by the post-obit lines being removed from the Dragon contour's options.ini file:

    SpeakerLanguageID=0
    Created With Wizard=1
    Dictation Source=eighteen

    DM360NE
    DMPE
    SOLUTION:

    To resolve this issue, delight refer to iSupport Solution:

    16072: Dragon Medical: Power Outage causes either missing PowerMic 2 Dictation Source or unable to add together Mic-in Dictation Source

    Invalid Entry

    When a DMNE user enters their username and password into the DMNE client login window, an fault "Invalid Entry" is presented esulting in the disability to open their user profile.

    A cause of this mistake is that in that location is no Speech Node Collection assigned to the site under Site Details within the Dash Management Console (NMC).

    DM360NE SOLUTION:  

    Associate a Speech Node Collection with a Site through the Nuance Management Console (NMC). The speech nodes in a node collection only perform tasks against the user profiles from the site the collection is associated with.

    1. In the NMC console, in the Sites group, select Manage organizations & sites.
    2. On the Organizations screen, double-click a site.
    3. Select the DM360 Network Edition tab.
    4. Expand the Principal user profile section.
    5. Beside Chief user contour directories, select the Configure push.
    6. In the Master User Profile Directory Settings dialog box, in the Name field, enter a name for the new Main user profiles location.
    7. In the General tab, in the Speech Node Collection field, select a speech node collection to associate with this site.

      Notation: If you associate the "<None>" Speech Node Drove with a site, optimization volition not run on the user profiles at that site and the aforementioned mistake can be presented.

    Delight refer to the appropriate version of DNME Administrator's Guide for boosted data on configuring the NMC, under iSupport Solution 14111: Dragon Medical 360 | Network Edition User Documentation

    Site has no NASUNC location

    This error is commonly seen within the client dragon.log file. See the dragon.log file excerpt below for reference.

    07:38:41 [NMS] [NMS] System.ServiceModel.FaultException`1[System.ServiceModel.ExceptionDetail]: Site has no NASUNC location . (Fault Detail is equal to An ExceptionDetail, likely created by IncludeExceptionDetailInFaults=true, whose value is:
    07:38:41 System.Exception: Site has no NASUNC location.

    The term "NASUNC" is associated with having no path (UNC or other type) for the master profile location configured in NAS (an older term for Nuance Management Server (NMS)).

    This error is typically the issue of ane or both of the following Dash Direction Console (NMC) configuration mistakes:

    • No Speech Profile Location value is defined for this NMC Site
    • No Speech communication Node Drove value is selected for this NMC Site
    DM360NE
    SOLUTION:   

    To confirm and resolve both of the aforementioned configuration mistakes, follow the steps below later logging into the NMC.

    1. In the NMC console, in the Sites group, select Manage organizations & sites.
    2. On the Organizations screen, double-click a site.
    3. Select the DM360 Network Edition tab.
    4. Expand the Primary user contour section.
    5. Beside Master user profile directories, select the Configure button.
    6. Speech Profile Location

    7. In the Full general tab, verify that the values for the two (2) Speech communication Profile Locations are present and right.

      Speech Node Drove

      Associate a Speech Node Collection with a Site through the Nuance Management Console (NMC). The speech nodes in a node drove only perform tasks against the user profiles from the site the collection is associated with.

    8. In the Speech Node Collection drop-downwardly field, select a speech node drove to acquaintance with this site.

      Note: If you associate the "<None>" Speech Node Collection with a site, optimization will not run on the user profiles at that site and the aforementioned error tin can be presented.

    9. Click Save and and then Save over again.

    Please refer to the appropriate version of DNME Ambassador's Guide for additional data on configuring the NMC, under iSupport Solution:
    14111: Dragon Medical 360 | Network Edition User Documentation

    Besides, refer to iSupport Solution:
    16616: DMNE Mistake: "Site has no NASUNC location"

    ERROR: Voice communication File upgrades are not supported in this version

    The error message beneath is displayed because some files take go corrupt which tell the client what version the profile is. Since the Dragon Medical 360 | Network Edition (DMNE) client cannot read the version it thinks the version is not supported. What this means is that the profile is corrupt.

    DM360NE
    DMPE
    STATUS: SOLVED

    Stride ane: Clear the local cache

    1. Launch DMNE and at the login prompt, click Options.

    2. On the options page put check in box labeled "Delete my local profile only" and then click OK

    3. Have the user login as normal using domain\username and their AD password. The client will remove the local cache and download a fresh copy from the Master Profile Share.

    Step 2: If error persists after removing cache

    1. User should contact the local Dragon Administrator to restore the profile from the Dash Management Console. Instructions are non provided on restoring profiles in this document. Admin should run across grooming materials if needed.
    2. If errors persist after restore then the user will need to create a new profile
    3. Removing the profile and creating a new one
    4. Launch Dragon Medical Network Edition
    5. At the login Prompt Click Options

    6. On the options page put check in box labeled "Delete my profile and create new" then click OK

    7. Have the user login as normal using domain/username and their Ad password. The customer will remove the Main Profile Share and present the user with the new user wizard.

    Authored by David Savage.


    warbybroment.blogspot.com

    Source: https://isupportcontent.nuance.com/healthcare/16500/16543/DragonERRORmatrix.html